Schneider LC1D115004V7
Product details
Schneider Electric power contactor LC1D115004V7
Manufacturer: Schneider Electric
Designation: Power contactor 4-pole
Type: LC1D115004V7
Rated control supply voltage Us at AC 50 Hz: 400 V
Rated control supply voltage Us at AC 60 Hz: 400 V
Voltage type for actuation: AC
Rated operational current Ie at AC-1, 400 V: 200 A
Rated operational current Ie at AC-3, 400 V: 115 A
Rated operational power at AC-3, 400 V: 55 kW
Suitable for series mounting: No
Connection type main circuit: Screw connection
Number of NO contacts as main contacts: 4
Further details:
Contactor TeSys LC1D. 4 pole, 4 NO contacts. Coil 400 V AC.
Dimensions (WxHxD): 150 x 158 x 132 mm, weight: 2.86 kg.
Category: AC-1. Integrated bidirectional amplitude limiter diode.
Quick and easy set-up. Safe and durable power connection with Everlink and spring terminals.
Suitable for safety applications due to mechanically coupled contacts and mirror contacts.
Certifications: GL, LROS (Lloyds Register of Shipping), UL, RINA, CCC, BV, GOST, DNV, CSA.
Product standards according to EAN: 3389110178159.
Relay type | Power contactor |
input voltage | 400 V |
Electric current output | 200 A |
Output current type | AC |
Number of poles | 4x |
Item number | 33585044 |
Manufacturer | Schneider |
Category | Relays |
Manufacturer No. | LC1D115004V7 |
Release date | 17.5.2023 |
Relay type | Power contactor |
input voltage | 400 V |
Electric current output | 200 A |
Output current type | AC |
Switching function | Normally open |
Number of openers | 0x |
Number of closers | 4x |
Number of poles | 4x |
Smart home | Not compatible |
Country of origin | Czech Republic |
Scope of delivery | 1 pc. |
Length | 132 mm |
Width | 150 mm |
Product Safety |
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- SchneiderNot enough data
- 1.ABB0 %
- 1.Metz Connect0 %
- 1.Phoenix Contact0 %
- 1.Schneider Electric0 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- SchneiderNot enough data
- 1.Shelly2 days
- ABBNot enough data
- AqaraNot enough data
- EatonNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- SchneiderNot enough data
- 1.Metz Connect0 %
- 1.Phoenix Contact0 %
- 3.Tru Components0,3 %
- 4.Schalk1 %