Schneider Electric Trigger device
6 pieces in stock at supplier
number of poles2
Product details
Schneider Electric Thermal Magnetic Trip Unit C103MG040
Manufacturer: Schneider Electric
Designation: Thermal Magnetic Trip Unit TM40G
Generator Type: C103MG040
Overload Trip Current Setting: 28..40 A
Initial Value of Undelayed Short-Circuit Trip Setting Range: 80 A
Final Value of Undelayed Short-Circuit Trip Setting Range: 80 A
Rated Continuous Current Iu: 40 A
Voltage Type for Operation: AC/DC
Rated Control Supply Voltage Us at AC 50 Hz: 690 V
Rated Control Supply Voltage Us at AC 60 Hz: 690 V
Rated Control Supply Voltage Us at DC: 750 V
Number of Poles: 3
Short-Circuit Trip Function: Undelayed
With Earth Fault Protection Function: No
Motor Protection Type: Thermal/Magnetic Trip
The TM40G is a 3-pole thermal magnetic trip unit designed for use with ComPacT NSX 100/160 circuit breakers. This thermal magnetic trip unit, with a rated current of 40 A, is the best choice for generator protection applications. It features an adjustable thermal overload protection and a fixed magnetic protection against short circuits. This product is part of our EcoStruxure Power architecture when combined with the PowerTag NSX and ComPacT NSX base circuit breaker.
Circuit breaker type | Circuit breaker |
number of poles | 3 |
Length | 88.20 mm |
Width | 104.70 mm |
Item number | 33628207 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer No. | C103MG040 |
Release date | 17.5.2023 |
Circuit breaker type | Circuit breaker |
number of poles | 3 |
Rated current | 40 A |
Rated voltage | 690 V |
voltage type | AC |
Country of origin | Poland |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 18,08 kg |
Climate contribution | EUR 0,44 |
Items per sales unit | 1 pcs. |
Length | 88.20 mm |
Width | 104.70 mm |
Height | 60.60 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 5.ABB0,1 %
- 5.Schneider Electric0,1 %
- 7.Hager0,3 %
- 8.Steffen0,4 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Steffen0,6 %
- 3.Eaton0,7 %
- 4.Schneider Electric1,6 %
- 5.Siemens2,6 %
- 6.ABB3,1 %