Schneider Electric Safety module for eccentric presses, XPSOT3744
Product details
Schneider Electric OT disconnector XPSOT3744
Manufacturer: Schneider Electric
Designation: OT disconnector NW-Contr. 230VAC
Type: XPSOT3744
Type of electrical connection: Screw connection
Rated control supply voltage Us at AC 50 Hz: 230 V
Rated control supply voltage Us at AC 60 Hz: 230 V
Type of voltage for actuation: AC
Speed measuring range: 0 1/min
With detachable terminals: No
Signal evaluation: Single-channel
With start input: Yes
With feedback loop: Yes
Number of outputs, safety-related, non-delayed, contact-based: 1
Number of outputs, signalling function, non-delayed, contacting: 3
Number of outputs, signalling function, non-delayed, semiconductor: 4
Suitable for safety functions: Yes
SIL according to IEC 61508: 3
Performance level according to EN ISO 13849-1: Level e
Width: 200 mm
Height: 73 mm
Depth: 118 mm
Schneider Electric OT switch XPSOT3744: more details
Preventa safety relay XPS. Safety module for eccentric presses for safely stopping the press ram at top dead centre and for automatic overtravel control. The module enables the creation of self-monitoring, redundant control systems. The supply voltage is 230 VAC.
EAN: 3389110724769.
input voltage | 230 V |
Scope of delivery | OT switch-off XPSOT3744 |
Item number | 33588576 |
Manufacturer | Schneider Electric |
Category | Relays |
Manufacturer no. | XPSOT3744 |
Release date | 17.5.2023 |
input voltage | 230 V |
Manufacturer Type | XPSOT3744 |
Smart Home | Not compatible |
Country of origin | Indonesia |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Schneider Electric fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Scope of delivery | OT switch-off XPSOT3744 |
Length | 118 mm |
Width | 200 mm |
Height | 73 mm |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- 1.Schneider Electric0 %
- 2.Finder0,1 %
- 3.ABB0,2 %
- 3.Eltako0,2 %
- 5.Eaton0,3 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Hager0 days
- 1.Shelly0 days
- ABBNot enough data
- AqaraNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- 2.ABB0,8 %
- 3.Phoenix Contact1,1 %
- 4.Schneider Electric1,6 %
- 5.Shelly1,7 %
- 6.Metz Connect2,3 %