Schneider Electric Contactor 3 pole NO contact 115A 115VAC
Product details
The TeSys LC1D contactor from Schneider Electric is a high-performance electrical component designed for various industrial applications. With three normally open contacts and additional auxiliary contacts, including one normally open and one normally closed, this contactor provides reliable control of electrical loads. It is rated for a nominal operating power of up to 55 kW at 400 V AC-3 and can handle a maximum operating current of 115 A. The coil operates with an input voltage of 115 V AC, allowing for broad applicability in different electrical systems. The device is equipped with an integrated bidirectional amplitude-limiting diode, which enhances its lifespan and reliability. Its easy installation and secure connection technology with Everlink and spring terminals make it a practical choice for professionals.
- Mechanically linked contacts for increased safety
- Certifications from DNV, RINA, CSA, CCC, UL, GL, BV, LROS
- Suitable for safety applications
- Quick and easy setup
- Integrated bidirectional amplitude-limiting diode.
Relay type | Power contactor, Switching relay |
input voltage | 115 V |
Output voltage | 440 V |
Electric current output | 115 A |
Output current type | AC |
Number of poles | 3x |
Item number | 9730028 |
Manufacturer | Schneider Electric |
Category | Relays |
Manufacturer No. | LC1D115FE7 |
Release date | 24.9.2018 |
Relay type | Power contactor, Switching relay |
input voltage | 115 V |
Output voltage | 440 V |
Electric current output | 115 A |
Output current type | AC |
Switching function | Normally open |
Number of openers | 0x |
Number of closers | 3x |
Number of poles | 3x |
Country of origin | Czech Republic |
Manufacturer commitment | RE100, SBTi |
Scope of delivery | 1 pc. |
Length | 136 mm |
Width | 120 mm |
Product Safety |
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- 1.Metz Connect0 %
- 1.Phoenix Contact0 %
- 1.Schneider Electric0 %
- 5.Finder0,1 %
- 6.Eaton0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Shelly2 days
- ABBNot enough data
- AqaraNot enough data
- EatonNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- 8.Finder2,8 %
- 9.Eaton3,1 %
- 9.Schneider Electric3,1 %
- 11.Eltako3,5 %
- 12.Siemens4 %