Schneider Electric Contactor,3P,Spl,25A AC3 11KW 1NO1NC 220Vdc
Product details
Range = TeSys D
Series = LC1D
Number of poles = 3
Coil voltage = 220 Vdc
Nominal contact current = 25 A
Nominal contact voltage = 690 Vac/dc
Number of auxiliary contacts = 2
Connection type = screw fixing
length = 85mm
width = 45mm
Depth = 101mm
UL and CSA. Contactors with the suffix BL accept auxiliary contact blocks for front mounting (but only the 2-contact version) and do not accept contacts for side mounting. 3 pole contactors, DC controlled. Integrated coil fault suppression 3 NO poles Auxiliary contact configuration one NO, one NC Actuating time closing 12 to 22 ms Actuating time opening 4 to 19 ms.
input voltage | 220 V |
Scope of delivery | TeSys LC1D25MD power contactor |
Output voltage | 220 V |
Output current type | AC |
Electric current output | 25 A |
Relay type | Power contactor |
Item number | 9718292 |
Manufacturer | Schneider Electric |
Category | Relays |
Manufacturer no. | LC1D25MD |
Release date | 24.9.2018 |
Relay type | Power contactor |
input voltage | 220 V |
Output voltage | 220 V |
Electric current output | 25 A |
Output current type | AC |
Switching function | Normally open |
Number of openers | 1 x |
Number of closers | 3 x |
Number of poles | 3 x |
Max. Switching capacity | 11 kW |
Manufacturer Type | LC1D25MD |
Smart Home | Not compatible |
Country of origin | France |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Schneider Electric fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Scope of delivery | TeSys LC1D25MD power contactor |
Length | 101 mm |
Width | 45 mm |
Height | 85 mm |
Weight | 530 g |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- 1.Schneider Electric0 %
- 2.Finder0,1 %
- 3.ABB0,2 %
- 3.Eltako0,2 %
- 5.Eaton0,3 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Shelly2 days
- ABBNot enough data
- AqaraNot enough data
- EatonNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- 1.Schalk0,4 %
- 2.Schneider Electric0,7 %
- 3.Phoenix Contact1,2 %
- 4.ABB1,5 %
- 5.Shelly1,7 %