Schneider Electric LC2D80ABBE 3p+1S+1Ö 37kW/400V/AC3 80A coil 24V DC reversing contactor combination
Product details
Reversing contactor combination with electronic control for the highest demands - TeSys D. This 3-phase unit has a rated current of 80 A for a motor power of up to 45 kW at 400 V AC3 and a supply voltage of 24 DC (500 mA), optimized for PLC outputs. It complies with the standards EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, EN/IEC 60947-5-1 and is certified according to CCC, CSA, UL, and EAC. Features include low-maintenance EverLink connection technology (removable) and two integrated auxiliary contacts that can be used for safety applications, with optimized width. This product meets the highest requirements in the field of switching technology and can be used for loads of all energy efficiency classes IE0 - IE4. When combined with TeSys GV3 or LR.D, it becomes an extremely compact reversing starter.
Relay type | Power contactor |
input voltage | 24 V |
Output voltage | 24 V |
Electric current output | 80 A |
Output current type | AC |
Number of poles | 3x |
Item number | 31991506 |
Manufacturer | Schneider Electric |
Category | Relays |
Manufacturer No. | LC2D80ABBE |
Release date | 24.10.2022 |
Relay type | Power contactor |
input voltage | 24 V |
Output voltage | 24 V |
Electric current output | 80 A |
Output current type | AC |
Switching function | Toggle switch |
Number of openers | 1x |
Number of closers | 1x |
Number of poles | 3x |
Max. Switching capacity | 37 kW |
Smart home | Not compatible |
Country of origin | France |
Manufacturer commitment | RE100, SBTi |
Scope of delivery | 1x reversing contactor combination |
Length | 120 mm |
Width | 119 mm |
Height | 122 mm |
Product Safety |
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- 1.Metz Connect0 %
- 1.Phoenix Contact0 %
- 1.Schneider Electric0 %
- 5.Finder0,1 %
- 6.Eaton0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Shelly2 days
- ABBNot enough data
- AqaraNot enough data
- EatonNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- 8.Finder2,9 %
- 9.Eaton3,1 %
- 10.Schneider Electric3,2 %
- 11.Eltako3,5 %
- 12.Aqara3,9 %