Schneider Electric Power contactor, 4p, 20A/AC1, coil 230V LC1K12004P7
More than 10 items ordered
Product details
Schneider Electric power contactor LC1K12004P7
Manufacturer: Schneider Electric
Designation: Power contactor
Type: LC1K12004P7
Rated control supply voltage Us at AC 50 Hz: 230 V
Rated control supply voltage Us at AC 60 Hz: 230 V
Voltage type for actuation: AC
Rated operational current Ie at AC-1, 400 V: 20 A
Rated operational current Ie at AC-3, 400 V: 12 A
Rated operational power at AC-3, 400 V: 5.5 kW
Suitable for series mounting: No
Connection type main circuit: Screw connection
Number of NO contacts as main contacts: 4
Further details:
Contactor TeSys 0, 4 pole, 4 NO contacts. Coil 230 V AC. Category AC-1. Simple machine control in industrial, infrastructure, and building applications. Easy-to-use interface for electronic devices (PLC). Certifications according to UL, CSA. Product standards according to EAN: 3389110126761.
Relay type | Power contactor |
input voltage | 230 V |
Electric current output | 20 A |
Output current type | AC |
Number of poles | 4x |
Item number | 33584636 |
Manufacturer | Schneider Electric |
Category | Relays |
Manufacturer No. | LC1K12004P7 |
Release date | 17.5.2023 |
Relay type | Power contactor |
input voltage | 230 V |
Electric current output | 20 A |
Output current type | AC |
Switching function | Normally open |
Number of openers | 0x |
Number of closers | 4x |
Number of poles | 4x |
Max. Switching capacity | 5.50 kW |
Country of origin | France |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,74 |
Scope of delivery | 1 pc. |
Length | 57 mm |
Width | 45 mm |
Height | 58 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- 1.Metz Connect0 %
- 1.Phoenix Contact0 %
- 1.Schneider Electric0 %
- 5.Finder0,1 %
- 6.Eaton0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Shelly2 days
- ABBNot enough data
- AqaraNot enough data
- EatonNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- 8.Finder3 %
- 9.Eaton3,1 %
- 9.Schneider Electric3,1 %
- 11.Eltako3,5 %
- 12.Siemens4 %