Preventa XPS universal safety relay. This multifunctional safety relay is designed for a wide range of safety applications, featuring selectable safety functions and a start option via a rotary switch on the front, along with diagnostic communication to the PLC. It is suitable for mechanical contacts in emergency stop, position or magnetic switches, as well as electronic PNP sensors, light curtains, or RFID safety switches with OSSD outputs. The selectable start functions include automatic, manual, or monitored start, as well as a start-up test. It has one safety circuit (redundant) and allows for the selection of one of six safety functions. The relay outputs are 3S safe, with 1T diagnostics. The clocked output transmits extensive diagnostic data to the PLC at standard input and evaluation via FB. The safety level is PL e, Cat. 4, SIL3. The supply voltage is 24 VAC/DC, and it features removable spring-loaded terminals and a lateral plug connector for direct connection of contact extension without wiring.
input voltage | 24 V |
Electric current output | 1.10 A |
Number of poles | 3x |
Item number | 32037014 |
Manufacturer | Schneider Electric |
Category | Relays |
Manufacturer No. | 135033 |
Release date | 24.10.2022 |
input voltage | 24 V |
Electric current output | 1.10 A |
Switching function | Normally open |
Number of openers | 1x |
Number of closers | 3x |
Number of poles | 3x |
Max. Switching capacity | 0 kW |
Smart home | Not compatible |
Country of origin | Indonesia |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,74 |
Scope of delivery | 1 piece |
Length | 120 mm |
Width | 22.50 mm |
Height | 100 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- 1.Metz Connect0 %
- 1.Phoenix Contact0 %
- 1.Schneider Electric0 %
- 5.Finder0,1 %
- 6.Eaton0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Shelly2 days
- ABBNot enough data
- AqaraNot enough data
- EatonNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- 8.Finder2,9 %
- 9.Eaton3,1 %
- 10.Schneider Electric3,3 %
- 11.Eltako3,5 %
- 12.Aqara3,9 %