Schneider LC1D80ND
Product details
Schneider Electric Contactor LC1D80ND
Manufacturer: Schneider Electric
Designation: Contactor 80A, 60VDC
Type: LC1D80ND
Rated control supply voltage Us at DC: 60 V
Voltage type for actuation: DC
Rated operating current Ie at AC-1, 400 V: 125 A
Rated operating current Ie at AC-3, 400 V: 80 A
Rated operating power at AC-3, 400 V: 37 kW
Rated operating current Ie at AC-4, 400 V: 32 A
Rated operating power at AC-4, 400 V: 15 kW
Suitable for series installation: No
Number of auxiliary contacts as NO contacts: 1
Number of auxiliary contacts as NC contacts: 1
Connection type main circuit: Screw connection
Number of NO contacts as main contacts: 3
The TeSys LC1D contactor features 3 poles with 3 NO contacts. Additional auxiliary contacts include 1 NO contact and 1 NC contact. Rated operating power at AC-3, 400 V is 37 kW, and rated operating current Ie at AC-3, 400 V is 80 A, with a coil voltage of 60 V DC.
Dimensions (WxHxD): 85 x 127 x 186 mm
Weight: 2.59 kg
Category: AC-1, AC-4, AC-3
Without integrated circuit module. Quick and easy to set up. Safe and durable power connection with Everlink and spring terminals. Suitable for safety applications thanks to mechanically coupled contacts and mirror contacts.
Certifications include LROS, CSA, GL, RINA, UL, CCC, BV, DNV, and GOST.
Product standards according to EAN: 3389110442632.
Relay type | Power contactor |
input voltage | 60 V |
Output voltage | 400 V |
Electric current output | 80 A |
Output current type | AC |
Number of poles | 3x |
Item number | 33586477 |
Manufacturer | Schneider |
Category | Relays |
Manufacturer No. | LC1D80ND |
Release date | 17.5.2023 |
Relay type | Power contactor |
input voltage | 60 V |
Output voltage | 400 V |
Electric current output | 80 A |
Output current type | AC |
Switching function | Normally open, Opener |
Number of openers | 1x |
Number of closers | 3x |
Number of poles | 3x |
Max. Switching capacity | 37 kW |
Country of origin | Czech Republic |
Scope of delivery | 1 pc. |
Width | 85 mm |
Height | 127 mm |
Product Safety |
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- SchneiderNot enough data
- 1.ABB0 %
- 1.Metz Connect0 %
- 1.Phoenix Contact0 %
- 1.Schneider Electric0 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- SchneiderNot enough data
- 1.Shelly2 days
- ABBNot enough data
- AqaraNot enough data
- EatonNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- SchneiderNot enough data
- 1.Metz Connect0 %
- 1.Phoenix Contact0 %
- 3.Tru Components0,3 %
- 4.Schalk1,2 %