EVN 200 Electronic transformer 100-200 W
This page always stays fresh and updates automatically.
200 Electronic transformer 100-200 W.

EVN 200 Electronic transformer 100-200 W
Primary nominal voltage: 415 V
Secondary nominal voltage: 0 → 415 V, 0 → 470 V
Nominal power: 8.14 kVA
Mounting type: Surface-mounted
Direction of knob rotation: Clockwise
Number of phases: 3
Number of outputs: 3
Connection type: Cable termination
Weight: 33.5 kg
Dimensions: 200 x 250 x 425 mm
Secondary current: 10 A
Depth: 425 mm
Length: 200 mm
Protection: Overload protection
Encapsulated control transformer. Professional transformers with a cast design available in single-phase or three-phase versions. The transformers are not designed for line separation but operate with mains voltage. All transformers must be grounded via the grounding terminals. A robust series of encapsulated variable transformers for SMD floor or wall mounting. Single-phase and three-phase versions available in various current ratings. Continuously variable AC output voltage with overvoltage connection. Sturdy construction, high efficiency, excellent regulation, no waveform distortion, silver-plated commutator, overload capability, smooth linear output, low maintenance, interference-free, and long service life.

Regulated isolation transformer for AC voltage regulation in laboratories, testing fields, and service workshops, as the built-in isolation transformer ensures galvanic separation between the primary and secondary sides. Robust, stable metal housing and carrying handle for mobile use. Display instruments for current and voltage. Indicator light, fuse, circuit breaker, output via a socket without protective contact.

Thalheimer LTS 604 Laboratory isolating transformer adjustable 1000 VA Number of outputs: 1 x 2
The portable isolation transformer from RS Pro is a reliable solution for applications that require safe separation from power sources. With a rated power of 3 kVA, this device is ideal for use on construction sites or in workshops where temporary power supply is needed. The transformer offers both a primary and secondary rated voltage of 230 V, making it versatile. Its robust construction and weight of 18 kg ensure stability and durability, while the protective contact plug allows for easy and safe connection. The transformer is designed to operate at frequencies from 50 Hz to 60 Hz and has an IP44 protection rating, which protects it from dust and splashes. These features make it a practical choice for professionals who value safety and efficiency.
- IP44 protection rating for additional protection against dust and splashes
- Suitable for use at frequencies from 50 Hz to 60 Hz
- Robust construction for use in demanding environments
- Easy handling with protective contact plug and standalone mounting.

Primary nominal voltage = 240V
Secondary nominal voltage = 0 → 240 V, 0 → 270 V
Rated power = 480VA
Mounting type = Surface mount
Knob rotation direction = Clockwise
Number of phases = 1
Number of outputs = 1
Connection type = Cable termination
Weight = 3.8kg
Dimensions = 160 x 130 x 160mm
Secondary current = 2A
Depth = 160mm
Length = 160mm
Width = 130mm
Encapsulated regulating transformer. Professional transformers with encapsulated design in single or three-phase version. The transformers are not designed for mains isolation but operate on mains voltage. All transformers must be grounded through the ground connection studs. A robust range of encapsulated variable transformers for SMD floor or wall mounting Single and three phase versions available in a wide range of current ratings Infinitely variable AC output voltage with overvoltage connection Heavy duty construction High efficiency, excellent regulation No waveform distortion Silver plated commutator Overload capacity Uniform linear output Low maintenance Hassle free and long life.

The P 2240 separates the galvanic connection of the output voltage from the power grid. The output voltage has no reference to ground potential and provides protection against electrical faults.
A galvanic isolation between primary and secondary voltage during measurements and repairs on open devices ensures a high safety standard for the user.
Despite a sturdy housing and a high output power of 500 W through the internal transformer, the measuring device weighs only a few kilograms, allowing for excellent mobility in everyday work.
For professional and safe repairs in service workshops, schools, or industry, the isolation transformer is the perfect choice. See for yourself.
Input voltage: 230 V AC ~ 50/60 Hz; Output voltage: 230 V AC ~ 50/60 Hz; Output power/continuous current 500 W. Accessories: power cable, spare fuse, manual. Dimensions: 160 x 125 x 235 mm. Weight: 7.5 kg.

Primary nominal voltage: 230 V AC, 245 V AC, 400 V AC, 415 V AC
Secondary nominal voltage: 230 V AC
Rated power: 500 VA
Mounting type: DIN rail
Number of outputs: 1
Length: 120 mm
Width: 143 mm
Depth: 130 mm
Dimensions: 120 x 143 x 130 mm
Operating frequency min.: 50 Hz
Operating frequency max.: 60 Hz
Maximum temperature: +35 °C
Weight: 7.5 kg
Switchgear primary 230/400 VAC with +15 VAC tap. High-quality safety and control isolation transformers for use in control circuits and general applications. Low loss noise lamination. Double standard primary winding 230 / 400 VAC with +15 V tap for input flexibility. Dual secondary windings with center tap. Grounding connection included. Fully lacquer-impregnated for protection against moisture and rust. Fully encapsulated cage connection with voltage markings. Detailed product data on a permanent label. High efficiency, low regulation.

Primary nominal voltage: 240V
Secondary nominal voltage: 0 to 240V, 0 to 270V
Rated power: 1.2kVA
Mounting type: Surface mount
Direction of knob rotation: Clockwise
Number of phases: 1
Number of outputs: 1
Connection type: Cable connection
Weight: 8.8kg
Dimensions: 175 x 175 x 140mm
Secondary current: 5A
Depth: 140mm
Length: 175mm
Width: 175mm
Encapsulated control transformer. Professional transformers with a cast design available in single-phase or three-phase versions. The transformers are not designed for line insulation but operate with mains voltage. All transformers must be grounded via the grounding connections. A robust series of encapsulated variable transformers for SMD floor or wall mounting. Single-phase and three-phase versions available in various current ratings. Continuously adjustable AC output voltage with surge protection connection. Sturdy construction, high efficiency, excellent regulation, no waveform distortion, silver-plated commutator, overload capability, smooth linear output voltage, low maintenance, interference-free, and long lifespan.

Secondary nominal voltage = 2 x 115V AC
Rated power = 630VA
Mounting type = Screw mounting
Length = 150mm
Width = 112mm
Depth = 158mm
Dimensions = 150 x 156 x 158mm
Operating frequency min. = 50Hz
Operating frequency max. = 60Hz
Weight = 7.9kg
RS Pro transformers with universal input. This series of input transformers from our trusted brand RS Pro are high quality and suitable for use in general applications. They are single-phase transformers with screw terminals for universal input voltages, with brackets for screw mounting or mounting on DIN rails. DIN rail mounting is only intended for transformers up to 250 VA. These input transformers have passed a 100% dielectric test and electrical testing, and feature a low-loss and low-noise core. These transformers come with a built-in earth connection terminal and a primary winding with multiple taps. High efficiency, low regulation, varnish impregnated, temperature class B. The technical specifications of the product can be found on the label.

Safety isolation transformer according to EN 60601-1 suitable for medical devices in accordance with the Medical Devices Act (MPG). Ideal for meeting the galvanic isolation requirements of medical devices from the power supply network as mandated by the MPG. The device is equipped with inrush current limitation and a robust steel sheet housing.

Thalheimer Laboratory isolating transformer fixed voltage ERT 230/23