ABB S-ARC1 C16
5 items in stock at supplier
Product details
Arc Fault Detection Device (AFDD) with Miniature Circuit Breaker (MCB) according to IEC/EN 62606 (VDE 0665-10) and IEC/EN 60898-1 (VDE 0641-11) provides protection against series and parallel arc faults, overcurrent protection (overload or short circuit), surge protection (only for internal AFDD), and protection against electrically ignited fires in accordance with DIN VDE 0100-420. Mandatory application areas according to DIN VDE 01000 are in single-phase AC systems with In = 16 A in sleeping or living areas of homes and day care facilities for children, disabled or elderly people, or in barrier-free apartments, as well as in rooms or locations with fire risk (with special fire hazards, fire-endangered workplaces), predominantly made of combustible building materials. The risk of irreplaceable goods - cultural assets with particularly high value and in single-phase final circuits that supply electrical equipment in the mentioned areas or cross these areas must also be considered. The use of AFDDs is recommended in rooms with sleeping facilities, rooms or locations with fire-spreading structures, and final circuits with high connection power. Generally, the AFDD is also recommended to enhance fire protection against electrically ignited fires. LED indicator to identify the cause of tripping. Top or bottom feeding is flexible, cross-wiring, for example, to RCDs in the rear terminal area is possible. System accessories can be attached to the M compact® system. Rated breaking capacity according to IEC/EN 60898-1 Icn=6kA. AFDD+MCB S-ARC1 is single-pole protected (LS), double-pole switching.
Circuit breaker type | FI fire protection switch |
Length | 69 mm |
Width | 2 mm |
number of poles | 2 |
Item number | 31996517 |
Manufacturer | ABB |
Category | Residual-current device |
Manufacturer no. | 2CSA255901r9164 |
Release date | 24.10.2022 |
Circuit breaker type | FI fire protection switch |
number of poles | 2 |
Tripping characteristic | C |
Rated voltage | 230 V |
voltage type | AC |
Rated insulation voltage Ui | 230 V |
Residual current (rated differential current) | 6000 A |
Protection type (IP code) | IP40 |
Country of origin | Italy |
Manufacturer commitment | SBTi |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 69 mm |
Width | 2 mm |
Product Safety |
30-day right of return if unopened
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0,2 %
- 5.ABB0,3 %
- 5.Hager0,3 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- LegrandNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 1.Brennenstuhl1,4 %
- 2.ABB1,8 %
- 2.Legrand1,8 %
- 2.Schneider Electric1,8 %
- 5.Siemens2 %