Schneider Electric FiBlock Vigi NG25 3p
Product details
The FiBlock Vigi NG25 3p from Schneider Electric is a highly advanced distribution cabinet accessory designed for use in demanding electrical installations. With a rated current of 125A and a rated residual current of 30mA, this RCD block provides comprehensive protection against electrical faults. It is specifically intended for mounting on circuit breakers of the NG125 series and allows for the combination into an RCD/circuit breaker. The innovative SI design ensures that unwanted tripping is avoided in critical applications, such as telecommunications or data centers. The FiBlock guarantees high immunity to transient leakage currents that can be caused by various electrical devices. Additionally, optional auxiliary modules can be added to integrate extra functions such as the display of switching positions or fault trippings. With its robust construction and versatile applications, the FiBlock Vigi NG25 3p is a reliable choice for modern electrical installations.
- Type A-SI for additional protection against fault currents
- High electrical immunity against transient leakage currents
- Prevents unwanted tripping in critical applications
- Compatible with circuit breakers of the NG125 series
- Optional auxiliary modules for extended functions.
Protection type (IP code) | IP20 |
Width | 180 mm |
Height | 118 mm |
Item number | 12900472 |
Manufacturer | Schneider Electric |
Category | Wiring closet technology |
Manufacturer No. | 19100 |
Release date | 12.3.2020 |
Nominal current | 125 A |
Protection type (IP code) | IP20 |
Nominal voltage | 415 V |
number of poles | 3 |
Tripping characteristic | A |
Residual current | 0.03 A |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,74 |
Items per sales unit | 1 pcs. |
Width | 180 mm |
Height | 118 mm |
Depth | 81 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Wiring closet technology» category have a defect within the first 24 months?
Source: Galaxus- Schneider ElectricNot enough data
- 1.BGS0 %
- 2.Knipex0,1 %
- 3.Hager0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- BGSNot enough data
- HagerNot enough data
- KnipexNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Wiring closet technology» category returned?
Source: Galaxus- Schneider ElectricNot enough data
- 1.BGS0,4 %
- 2.Knipex0,6 %
- 3.Hager2,9 %