Schneider Electric Motor protection switch
Product details
Schneider Electric motor-protective circuit-breaker GV2ME21TQ
Manufacturer: Schneider Electric
Designation: Motor-protective circuit-breaker
Current setting: 17-23 A
Setting range of instantaneous short-circuit release: 327 A
With thermal protection: Yes
Phase loss sensitive: Yes
Tripping technology: Thermomagnetic
Rated operational voltage: 0-690 V
Rated uninterrupted current Iu: 23 A
Rated operating power at AC-3, 230 V: 5.5 kW
Rated operating power at AC-3, 400 V: 9 kW
Connection type main circuit: Screw connection
Design of actuating element: Pushbutton
Unit design: Complete unit in enclosure
With integrated auxiliary contact: No
With integrated undervoltage release: No
Number of poles: 3
Rated short-circuit breaking current Icu at 400 V, AC: 15 kA
Degree of protection (IP): IP20
Height: 89 mm
Width: 45 mm
Depth: 78.2 mm
Schneider Electric motor-protective circuit-breaker GV2ME21TQ: further details
Motor-protective circuit-breakers with thermal and magnetic tripping. These devices are easy to operate and set up, with compact and ergonomic products for starter motor and stop motor requirements.
EAN: 3389110343229.
Circuit breaker type | Motor protection switch |
Length | 78.20 mm |
Width | 45 mm |
mounting style | Screws |
number of poles | 3 |
Item number | 36805492 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | GV2ME21TQ |
Release date | 28.6.2023 |
Circuit breaker type | Motor protection switch |
mounting style | Screws |
number of poles | 3 |
Tripping characteristic | Sluggish --- |
voltage type | AC/DC |
Protection type (IP code) | IP20 |
Country of origin | France |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 78.20 mm |
Width | 45 mm |
Height | 89 mm |
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0,2 %
- 5.ABB0,3 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- LegrandNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 4.Legrand1,9 %
- 5.Siemens2 %
- 6.Schneider Electric2,1 %
- 7.Eaton4,3 %
- 8.Hager4,5 %