Schneider Electric PrismaSeT-P
3 items ordered
Product details
Schneider Electric PrismaSeT-P, Linergy DX LVS04046
Manufacturer: Schneider Electric
Designation: PrismaSeT-P, Linergy DX distribution block, 4-pole
Type: LVS04046
Number of poles: 4
Rated current: 160 A
Connection type: Screwless
Mounting type: DIN rail/screw
Suitable for solid conductors: No
Suitable for stranded conductors: No
Suitable for flexible conductors: No
Suitable for fine stranded conductors without ferrule: No
Suitable for extra-fine stranded conductors: No
Suitable for extra-fine stranded conductors without ferrule: No
Touch-proof: Yes
Height: 127 mm
Width: 108 mm
Depth: 48 mm
The PrismaSeT-P, Linergy DX distribution block is a 4-pole unit with a permissible current of up to 125 A. It features a pre-assembled infeed connection and outgoing connection capacity for cables of 7 x 4 mm² per phase, 3 x 6 mm² per phase, 2 x 10 mm² per phase, and 1 x 16 mm² per phase. It has a rated impulse withstand current (Ipk) of 20 kA, rated short-circuit current (Isc) of 150 kA with supply-side protection of 150 kA (Icc), and a rated insulation voltage (Ui) of 750 V AC. The rated voltage (Ue) is 690 V AC, with a rated impulse withstand voltage (Uimp) of 8 kV. It has a degree of protection IPxxB for mounting on a DIN rail or screwed onto a mounting plate, with a width of 6 module units (18 mm), a height of 127 mm, and a depth of 48 mm.
Protection type (IP code) | IP20 |
Width | 108 mm |
Height | 127 mm |
Item number | 33627015 |
Manufacturer | Schneider Electric |
Category | Wiring closet technology |
Manufacturer No. | LVS04046 |
Release date | 17.5.2023 |
Area of use | Inside |
Nominal current | 160 A |
Protection type (IP code) | IP20 |
Nominal voltage | 690 V |
number of poles | 4 |
breaking capacity | 150 kA |
Leakage current | 20 kA |
Country of origin | France |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,74 |
Items per sales unit | 1 pcs. |
Width | 108 mm |
Height | 127 mm |
Depth | 48 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Wiring closet technology» category have a defect within the first 24 months?
Source: Galaxus- Schneider ElectricNot enough data
- 1.BGS0 %
- 2.Knipex0,1 %
- 3.Hager0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- BGSNot enough data
- HagerNot enough data
- KnipexNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Wiring closet technology» category returned?
Source: Galaxus- Schneider ElectricNot enough data
- 1.BGS0,4 %
- 2.Knipex0,6 %
- 3.Hager2,9 %