Schneider Electric Residual current block
Product details
The differential current block from Schneider Electric, model Vigi NG125, is an essential accessory for distribution boards that ensures the safety of electrical installations. With a rated current of 63A and a rated residual current range of 300-3000mA, this 3-pole RCD block provides reliable protection against fault currents. The operating voltage ranges from 400-415V AC, while the insulation voltage is 690V AC. The differential current block is designed to be mounted on the right side of circuit breakers from the NG125 series, allowing for flexible installation. A mechanical indicator on the knob signals tripping due to fault current, and a test button enables regular functional checks. The thermomagnetic technology of the tripping unit ensures precise and reliable response to fault currents. The Vigi NG125 meets the standards IEC/EN 61009-1 and is VDE certified, highlighting its high quality and safety.
- Mechanical indicator for fault current tripping
- Test button for regular functional checks
- Thermomagnetic tripping unit for precise response
- Additional snap-on auxiliary modules available
- Complies with IEC/EN 61009-1 and VDE certification.
Protection type (IP code) | IP20 |
Width | 180 mm |
Item number | 12900653 |
Manufacturer | Schneider Electric |
Category | Wiring closet technology |
Manufacturer No. | 19036 |
Release date | 12.3.2020 |
Nominal current | 63 A |
Protection type (IP code) | IP20 |
Nominal voltage | 415 V |
number of poles | 3 |
Tripping characteristic | A |
Residual current | 0.30 A |
breaking capacity | 5 kA |
Input voltage | 230 V, 415 V |
Country of origin | France, Germany |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,74 |
Items per sales unit | 1 pcs. |
Width | 180 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Wiring closet technology» category have a defect within the first 24 months?
Source: Galaxus- Schneider ElectricNot enough data
- 1.BGS0 %
- 2.Knipex0,1 %
- 3.Hager0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- BGSNot enough data
- HagerNot enough data
- KnipexNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Wiring closet technology» category returned?
Source: Galaxus- Schneider ElectricNot enough data
- 1.BGS0,3 %
- 2.Knipex0,6 %
- 3.Hager2,8 %