Schneider Electric SCHN Mains switching
Product details
TA10D2S0403TPE is an automatic power transfer switch used in industrial and commercial buildings, data centers, healthcare facilities, and transportation. The rated operating voltage is 230 VAC at 50/60 Hz. This power switch is suitable for operation in the usage category AC-33B. The rated current can be loaded with 50 A at 60 °C, with a size range of 32-100 A. On the front, there is a built-in display module that can be used for local control and settings via rotary/dip switches. This switch features 3 switch positions on the front with mechanical and electrical indication. It can be mounted on a DIN rail or plate and positioned in an electrical distribution cabinet. There are also some optional accessories available for various applications. This 2-pole version measures 306 mm (width) x 145 mm (height) x 94.5 mm (depth). It complies with the IEC 60947-6-1 standard and is certified by CE/CB/CCC. It is suitable for power transmission of safety loads such as fire extinguishing systems, smoke extraction fans, sprinkler pumps, emergency lighting, etc.
Protection type (IP code) | IP20 |
Width | 306 mm |
Height | 145 mm |
Item number | 37794239 |
Manufacturer | Schneider Electric |
Category | Wiring closet technology |
Manufacturer No. | TA10D2S0403TPE |
Release date | 31.8.2023 |
Material group | Plastic |
Material | Plastic |
Area of use | Inside |
Nominal current | 40 A |
Protection type (IP code) | IP20 |
Nominal voltage | 230 V |
number of poles | 2 |
Input voltage | 230 V |
Control type | Manual |
Country of origin | China |
Manufacturer commitment | RE100, SBTi |
Items per sales unit | 1 pcs. |
Width | 306 mm |
Height | 145 mm |
Depth | 94.50 mm |
Product Safety |
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Wiring closet technology» category have a defect within the first 24 months?
Source: Galaxus- Schneider ElectricNot enough data
- 1.BGS0 %
- 2.Knipex0,1 %
- 3.Hager0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- BGSNot enough data
- HagerNot enough data
- KnipexNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Wiring closet technology» category returned?
Source: Galaxus- Schneider ElectricNot enough data
- 1.BGS0,3 %
- 2.Knipex0,6 %
- 3.Hager2,9 %