Schneider Electric Schneider PrismaSeT-P LinergyLVS04034DP distribution block 4-pole 250A
1 item ordered
Product details
Schneider Electric PrismaSeT-P, Linergy DP LVS04034
Manufacturer: Schneider Electric
Designation: PrismaSeT-P, Linergy DP distribution block, 4-pole
Type: LVS04034
Number of poles: 4
Rated current: 250 A
Connection type: Screwless
Mounting type: DIN rail
Suitable for solid conductors: No
Suitable for stranded conductors: No
Suitable for fine-stranded conductors: No
Suitable for fine-stranded conductors without ferrules: No
Touch-proof: Yes
Height: 140 mm
Width: 140 mm
Depth: 64 mm
Further details: PrismaSeT P, Linergy DP distribution block 4-pole with a permissible current rating up to 250 A. Supply connection directly to a ComPacT NSX or ComPacT INS up to 250 A. Connection capacity on the outgoing side for cables of 6 x 10 mm² per phase and 3 x 16 mm² per phase. Rated impulse withstand current (Ipk) of 30 kA, rated short-time withstand current (Icw) of 8.5 kA eff./1s, rated insulation voltage (Ui) of 750 V AC, rated voltage (Ue) of 690 V AC. Rated impulse withstand voltage (Uimp) 8 kV, with protection class IPxxB for mounting on a DIN rail or on a mounting plate with a width of 140 mm, a height of 138 mm, and a depth of 64 mm.
Protection type (IP code) | IP65 |
Width | 140 mm |
Height | 140 mm |
Item number | 33627013 |
Manufacturer | Schneider Electric |
Category | Wiring closet technology |
Manufacturer No. | LVS04034 |
Release date | 17.5.2023 |
Exact colour description | Grey |
Material group | Plastic |
Nominal current | 250 A |
Protection type (IP code) | IP65 |
Nominal voltage | 690 V |
number of poles | 4 |
Country of origin | France, Poland |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,74 |
Items per sales unit | 1 pcs. |
Width | 140 mm |
Height | 140 mm |
Depth | 64 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Wiring closet technology» category have a defect within the first 24 months?
Source: Galaxus- Schneider ElectricNot enough data
- 1.BGS0 %
- 2.Knipex0,1 %
- 3.Hager0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- BGSNot enough data
- HagerNot enough data
- KnipexNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Wiring closet technology» category returned?
Source: Galaxus- Schneider ElectricNot enough data
- 1.BGS0,3 %
- 2.Knipex0,6 %
- 3.Hager2,8 %