Schneider Electric Over- or undervoltage between phases
Only 3 pieces in stock at supplier
Product details
Monitoring Applications: Voltage
Supply Voltage: 120 to 277 V AC
Contact Arrangement: 2-pole switch
Electrical Phases: 3
Voltage Measurement Range: 114 to 329 V AC
Delay Time: 0.3 to 30 s
Width: 35 mm
UL, CSA, GL, C-Tick, GOST. NF EN 60255-6 and IEC 60255-6. RM17 UB3 and RM35 UB3 three-phase voltage monitors. Schneider Electric RM17/35 UB measuring and control relays for three-phase power supply monitor the correct sequence of phases L1, L2, and L3. It also monitors the total failure of one or more phases, asymmetry, as well as overvoltage and undervoltage with independent settings. In the event of a voltage fault, the relay will open at the end of the user-defined delay time. If the device is powered on with a measured fault, the relay remains open. The relay will open immediately in the event of a neutral conductor failure or phase loss. It checks its own power supply. Transparent front panel with hinges. Potentiometer selects voltages between phases. LED display of output status. DIN rail mounting.
input voltage | 120 V |
Scope of delivery | Overvoltage/undervoltage RM35UB3N30, Voltage monitor |
Output voltage | 120 V |
Output current type | AC, DC |
Relay type | Overload relay |
Item number | 9716117 |
Manufacturer | Schneider Electric |
Category | Relays |
Manufacturer no. | RM35UB3N30 |
Release date | 24.9.2018 |
External links |
Relay type | Overload relay |
input voltage | 120 V |
Output voltage | 120 V |
Output current type | AC, DC |
Manufacturer Type | RM35UB3N30 |
Smart Home | Not compatible |
Country of origin | Indonesia |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Schneider Electric fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Scope of delivery | Overvoltage/undervoltage RM35UB3N30, Voltage monitor |
Length | 72 mm |
Width | 35 mm |
Height | 90 mm |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Relays» category have a defect within the first 24 months?
Source: Galaxus- 1.Schneider Electric0 %
- 2.Finder0,1 %
- 3.ABB0,2 %
- 3.Eltako0,2 %
- 5.Eaton0,3 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- 1.Hager0 days
- 2.Shelly2 days
- ABBNot enough data
- AqaraNot enough data
Return rate
How often is a product of this brand in the «Relays» category returned?
Source: Galaxus- 2.ABB0,8 %
- 3.Phoenix Contact1,2 %
- 4.Schneider Electric1,5 %
- 5.Shelly1,6 %
- 6.Eaton2,3 %