Product details
ABB Stotz S&J Contactor AF12Z-30-10-23
Manufacturer: ABB Stotz S&J
Designation: Contactor 100-250V AC/DC
Type: AF12Z-30-10-23
Rated control supply voltage Us at AC 50 Hz: 100 V
Rated control supply voltage Us at AC 60 Hz: 100 V
Rated control supply voltage Us at DC: 100 V
Voltage type for actuation: AC/DC
Rated operational current Ie at AC-1, 400 V: 28 A
Rated operational current Ie at AC-3, 400 V: 12 A
Rated operational power at AC-3, 400 V: 5.5 kW
Rated operational power NEMA: 3.72849999 kW
Suitable for rail mounting: no
Number of auxiliary contacts as normally open: 1
Connection type main circuit: screw connection
Number of normally open contacts as main contacts: 3
The 3-pole AF12Z contactors are designed for switching power circuits with motors, lightly inductive, or non-inductive loads. They feature an electronic coil interface that can accommodate a very wide control voltage range, allowing them to handle significant control voltage fluctuations. AFZ contactors can withstand short voltage drops and sags. All integrated or retrofittable auxiliary normally open contacts are designed as mirror contacts according to IEC60947-5-1 Annex L. Additionally, they have built-in surge protection and do not require additional extinguishing components. Further accessories such as time delay relays, wiring aids, and interlocking components complement the range.
number of poles | 3 |
Item number | 33604046 |
Manufacturer | ABB |
Category | Residual-current device |
Manufacturer No. | 1SBL156001R2310 |
Release date | 17.5.2023 |
number of poles | 3 |
Rated voltage | 400 V |
voltage type | AC/DC |
Country of origin | France |
Manufacturer commitment | RE100 |
Items per sales unit | 1 pcs. |
Product Safety |
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Max Hauri0 %
- 1.Siemens0 %
- 5.ABB0,1 %
- 5.Schneider Electric0,1 %
- 7.Hager0,3 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 3.Eaton0,7 %
- 4.Schneider Electric1,7 %
- 5.Siemens2,6 %
- 6.ABB3,1 %
- 7.Hager4,6 %