ABB Stotz S&J Contactor AF26-40-00-13
7 pieces in stock at supplier
Product details
ABB Stotz S&J Contactor AF26-40-00-13
Manufacturer: ABB Stotz S&J
Designation: Contactor
100-250V AC/DC
Type: AF26-40-00-13
Rated control supply voltage Us at AC 50 Hz: 100 V
Rated control supply voltage Us at AC 60 Hz: 100 V
Rated control supply voltage Us at DC: 100 V
Voltage type for actuation: AC/DC
Rated operating current Ie at AC-1, 400 V: 45 A
Rated operating current Ie at AC-3, 400 V: 22 A
Rated operational power at AC-3, 400 V: 11 kW
Rated operational power NEMA: 7.5 kW
Suitable for in-line installation: No
Connection type main circuit: Screw connection
Number of NO contacts as main contacts: 4
The 4-pole AF26 contactors represent the compact series with AC/DC control and very wide coil voltage ranges. They switch power circuits with motors, light inductive or non-inductive loads. Only 4 coils cover control voltages from 20 to 500 VDC and 24 to 500 VAC. They have integrated overvoltage protection and do not require additional suppressors. All auxiliary NC contacts that can be retrofitted are designed as mirror contacts according to IEC60947-5-1 Annex L. Other accessories such as timers, wiring aids, and locking elements complete the range.
number of poles | 4 |
Item number | 33604109 |
Manufacturer | ABB |
Category | Residual-current device |
Manufacturer No. | 1SBL237201R1300 |
Release date | 17.5.2023 |
number of poles | 4 |
Rated voltage | 100 V |
voltage type | AC/DC |
Insulation voltage (Ui) | 690 V |
Country of origin | France |
Manufacturer commitment | RE100 |
CO₂ emissions | 19,39 kg |
Climate contribution | EUR 0,49 |
Items per sales unit | 1 pcs. |
Product Safety |
Length | 11 cm |
Width | 9 cm |
Height | 5 cm |
Weight | 370 g |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Max Hauri0 %
- 1.Siemens0 %
- 5.ABB0,1 %
- 5.Schneider Electric0,1 %
- 7.Hager0,3 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 3.Eaton0,7 %
- 4.Schneider Electric1,5 %
- 5.Siemens2,6 %
- 6.ABB3,2 %
- 7.Hager4,7 %