Product details
The Chint FI circuit breaker/overcurrent protection switch is a reliable device designed for use in personal, fire, cable, and line protection. With a rated current of 25 A and a rated residual current of 0.03 A, it offers a high level of safety against overload and short circuits. The switch is capable of tripping for both slowly rising and sudden sinusoidal alternating currents, making it particularly versatile. Additionally, it provides protection against fault currents and offers preventive fire protection. The tripping characteristic B is ideal for the protection of systems and people, while characteristic C is suitable for the protection of resistive and inductive loads with low inrush current. With a rated voltage of 240 V and 415 V, this switch is suitable for various applications in electrical installations.
- Protection against overload and short circuits
- Preventive fire protection against fault currents
- Versatile tripping characteristics B and C
- Suitable for various voltage types.
Circuit breaker type | Miniature circuit breaker |
number of poles | 1 |
Length | 77 mm |
Width | 36 mm |
Item number | 32018360 |
Manufacturer | Chint |
Category | Residual-current device |
Manufacturer no. | 203009 |
Release date | 24.10.2022 |
Colour | Blue, White |
Exact colour description | Blue, white |
Circuit breaker type | Miniature circuit breaker |
number of poles | 1 |
Tripping characteristic | B |
Rated current | 25 A |
Rated current | 0.03 A |
Rated voltage | 240 V |
voltage type | AC |
Residual current (rated differential current) | 0.03 A |
CO₂ emissions | 29,26 kg |
Climate contribution | EUR 0,74 |
Length | 77 mm |
Width | 36 mm |
Height | 86 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- ChintNot enough data
- 1.Brennenstuhl0 %
- 1.Eaton0 %
- 1.Siemens0 %
- 4.ABB0,1 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ChintNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- ChintNot enough data
- 1.Max Hauri0,4 %
- 2.Steffen0,6 %
- 3.Eaton0,7 %
- 4.Schneider Electric1,3 %