Schneider A9D06620
Product details
The A9D06620 residual current protection block from Schneider is a highly advanced RCD/MCB that provides both overcurrent and residual current protection. With a rated current of 20 A and a ground fault sensitivity of 30 mA, this device ensures comprehensive protection for final circuits. It is designed for operation at a voltage of 110 V AC and complies with the IEC/EN 61009 and IEC/EN 60947-2 standards. The thermomagnetic tripping unit ensures reliable functionality, while the mechanically separated fault indication provides clear feedback on the device's status in the event of a fault. The tool-free installation and the option to connect additional auxiliary modules make the A9D06620 a flexible solution for various applications.
- Mechanically separated fault indication
- Test button for regular functional testing
- Thermomagnetic tripping unit for reliable protection
- Tool-free installation for easy setup
- Optional auxiliary modules for enhanced functionality.
Circuit breaker type | Fault current circuit breaker, Miniature circuit breaker, Miniature circuit-breaker/residual current circuit-breaker combination |
number of poles | 2 |
Item number | 31993942 |
Manufacturer | Schneider |
Category | Residual-current device |
Manufacturer No. | A9D06620 |
Release date | 24.10.2022 |
Colour | White |
Exact colour description | RAL 9003 |
Circuit breaker type | Fault current circuit breaker, Miniature circuit breaker, Miniature circuit-breaker/residual current circuit-breaker combination |
number of poles | 2 |
Tripping characteristic | B |
Rated voltage | 110 V |
voltage type | AC |
Insulation voltage (Ui) | 400 V |
Residual current | 0.03 A |
Protection type (IP code) | IP20 |
CO₂ emissions | 18,08 kg |
Climate contribution | EUR 0,44 |
Items per sales unit | 1 pcs. |
Height | 73 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- SchneiderNot enough data
- 1.Brennenstuhl0 %
- 1.Eaton0 %
- 1.Max Hauri0 %
- 1.Siemens0 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- SchneiderNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- SchneiderNot enough data
- 1.Max Hauri0,4 %
- 2.Steffen0,6 %
- 3.Eaton0,7 %
- 4.Schneider Electric1,6 %