Schneider EasyPact CVS100N circuit-breaker, 50kA at 415VAC, 32A, TM-D trip unit, 3P3d LV510472
Product details
EasyPact CVS100N is a 32 A circuit breaker. The breaking capacity (Icu) is 50 kA rms at 415 VAC 50/60 Hz. The circuit breaker is 3-pole and features a TM-D trip unit for thermal-magnetic protection. The breaker complies with the IEC 60947-2 standard for circuit breakers. This device is certified for operation in environments with pollution degree III according to IEC 60947-1 and IEC 60664-1, and it meets the RoHS requirements of the European environmental directive EC/2002/95. The front of the toggle lever offers protection class IP40, but when equipped with an extended rotary handle inside the switchgear, the extended rotary handle additionally has protection class IP54. This series has slots for electrical auxiliary devices (MN/MX/OF/SD). The dimensions are 140 mm in width, 255 mm in height, and 110 mm in depth.
Circuit breaker type | Circuit breaker |
Mounting type | Built-in installation |
number of poles | 3 |
Length | 110 mm |
Width | 140 mm |
Item number | 47141957 |
Manufacturer | Schneider |
Category | Residual-current device |
Manufacturer No. | LV510472 |
Release date | 10.7.2024 |
Circuit breaker type | Circuit breaker |
Mounting type | Built-in installation |
Mounting type | Screw fastening |
number of poles | 3 |
Rated current | 100 A |
Rated voltage | 440 V |
voltage type | AC |
Protection type (IP code) | IP40 |
Country of origin | India |
Items per sales unit | 1 pcs. |
Length | 110 mm |
Width | 140 mm |
Height | 255 mm |
Product Safety |
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- SchneiderNot enough data
- 1.Brennenstuhl0 %
- 1.Eaton0 %
- 1.Max Hauri0 %
- 1.Siemens0 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- SchneiderNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- SchneiderNot enough data
- 1.Steffen0,6 %
- 2.Eaton0,7 %
- 2.Max Hauri0,7 %
- 4.Schneider Electric1,4 %