Schneider Electric DC Release Device C104TM100D
Manufacturer: Schneider Electric
Designation: DC Release Device Thermomagnetic TM1
Type: C104TM100D
Overload Release Current Setting: 70..100 A
Initial Value of the Instantaneous Short-Circuit Release Setting Range: 800 A
Final Value of the Instantaneous Short-Circuit Release Setting Range: 800 A
Rated Continuous Current Iu: 100 A
Type of Voltage for Operation: DC
Number of Poles: 4
Short-Circuit Release Function: Instantaneous
With Earth Fault Protection Function: No
Type of Motor Protection: Thermal/Magnetic Release
The TM100DC is a thermomagnetic release device with 4 poles, used in the ComPacT NSX 100DC circuit breakers. This thermomagnetic release device, with a rated current of 100 A, is the optimal choice for all distribution applications. It features an adjustable thermal overload protection and a fixed magnetic protection against short circuits. The rated current is 100 A and the operating voltage is 750 VDC. It complies with international standards (IEC 60947), CCC, EAC, and marine specifications.
Circuit breaker type | Fault current circuit breaker |
number of poles | 4 |
Length | 88.20 mm |
Width | 139.70 mm |
Item number | 33627942 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer No. | C104TM100D |
Release date | 17.5.2023 |
Circuit breaker type | Fault current circuit breaker |
number of poles | 4 |
Rated current | 100 A |
Rated voltage | 750 V |
voltage type | DC |
Country of origin | Poland |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 18,08 kg |
Climate contribution | EUR 0,44 |
Length | 88.20 mm |
Width | 139.70 mm |
Height | 60.60 mm |
Product Safety |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 5.ABB0,1 %
- 5.Schneider Electric0,1 %
- 7.Hager0,3 %
- 8.Steffen0,4 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Steffen0,6 %
- 3.Eaton0,7 %
- 4.Schneider Electric1,5 %
- 5.Siemens2,7 %
- 6.ABB3,2 %