Schneider Electric Fehlerstrom-Schutzschalter
More than 10 pieces in stock at supplier
Product details
Schneider Electric residual current circuit-breaker R9R22440. Residual current circuit-breaker 3P+N,40A,30mA. Type: R9R22440. Number of poles: 4. Rated voltage: 400 V. Rated current: 40 A. Rated residual current: 0.03 A. Rated insulation voltage Ui: 440 V. Rated impulse withstand voltage Uimp: 4 kV. Mounting type: DIN rail. Residual current type: A. Short-circuit strength (Icw): 10 kA. Surge current resistance: 0.25 kA. Voltage type: AC. Frequency: 50 Hz. Additional equipment possible: yes. Protection class (IP): IP20. Width in pitch units: 4. Installation depth: 44 mm. Ambient temperature during operation: -25..40 °C. Pollution degree: 2. Connectable conductor cross-section stranded: 1..25 mm². Connectable conductor cross-section solid: 1..35 mm².
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Length | 78.50 mm |
Width | 72 mm |
Item number | 22724504 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer No. | R9R22440 |
Release date | 19.10.2022 |
External links |
Colour | Grey |
Exact colour description | Grey |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Tripping characteristic | A |
Rated current | 40 A |
Rated current | 0.03 A |
Rated voltage | 400 V |
voltage type | AC |
Insulation voltage (Ui) | 440 V |
Residual current | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | Spain |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 17,82 kg |
Climate contribution | EUR 0,44 |
Items per sales unit | 1 pcs. |
Length | 78.50 mm |
Width | 72 mm |
Height | 81 mm |
Weight | 340 g |
Product Safety |
Length | 9 cm |
Width | 9 cm |
Height | 8 cm |
Weight | 346 g |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 5.ABB0,1 %
- 5.Schneider Electric0,1 %
- 7.Hager0,3 %
- 8.Steffen0,4 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Steffen0,6 %
- 3.Eaton0,7 %
- 4.Schneider Electric1,5 %
- 5.Siemens2,7 %
- 6.ABB3,2 %