Product details
Residual current circuit breaker Acti 9 iID, 1.5 kA (IEC/EN 61008-1). 4-pole, rated current 40 A, earth fault sensitivity 100 mA, earth fault protection class type A, operating voltage (Ue) 400 V AC, insulation voltage (Ui) 500 V AC. Provides additional protection against direct contact (= 30 mA). Fault protection against indirect contact, e.g., in case of insulation faults (= 100 mA, = 300 mA). Fault protection in construction site distribution boards (500 mA). Switching and disconnecting circuits. Snap-action mechanism for low-wear switching of contacts. Equipped with a mechanical front-facing fault indication (VisiTrip) to display tripping due to overload or short circuit. Safe contact indication (VisiSafe) of the residual current circuit breaker, with a green display indicating safety from voltage on the outgoing side. Test button for regular functional testing. Double connection terminals for dual-sided connection of cables or busbars. Easy removal of the individual device with installed busbar, thanks to the front-accessible fastening element. Additional snap-on auxiliary modules (optional) - undervoltage release (iMN), overvoltage release (iMSU), working current release (iMX), auxiliary switch for status indication (iOF), fault indication switch (iSD). Tool-free mounting on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID complies with the following standards - IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified.
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Length | 44 mm |
Width | 72 mm |
Item number | 12899127 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer No. | A9Z22440 |
Release date | 12.3.2020 |
Colour | White |
Exact colour description | White |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Tripping characteristic | A |
Rated current | 40 A |
Rated voltage | 400 V |
voltage type | AC |
Insulation voltage (Ui) | 500 V |
Residual current | 0.10 A |
Protection type (IP code) | IP20 |
Country of origin | Spain |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 5,24 kg |
Climate contribution | EUR 0,13 |
Items per sales unit | 1 pcs. |
Length | 44 mm |
Width | 72 mm |
Height | 91 mm |
Product Safety |
Length | 11 cm |
Width | 9 cm |
Height | 8 cm |
Weight | 34 g |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 5.ABB0,1 %
- 5.Schneider Electric0,1 %
- 7.Hager0,3 %
- 8.Steffen0,4 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Steffen0,6 %
- 3.Eaton0,7 %
- 4.Schneider Electric1,5 %
- 5.Siemens2,7 %
- 6.ABB3,2 %