Schneider Electric FI/LS switch
More than 10 pieces in stock at supplier
Product details
Schneider Electric FI/LS switch R9D01610 Manufacturer: Schneider Electric Designation: FI/LS switch 1P+N, 10A, B-Char. Type: R9D01610 Number of poles (total): 2 Number of fused poles: 1 Rated voltage: 230 V Rated insulation voltage Ui: 400 V Rated impulse withstand voltage Uimp: 4 kV Rated current: 10 A Rated residual current: 0.03 A Fault current type: A Energy limitation class: 3 Rated breaking capacity according to EN 61009: 6 kA Rated breaking capacity Icn according to EN 61009-1: 6 kA Tripping characteristic: instantaneous Surge current withstand: 0.25 kA Voltage type: AC Frequency: 50 Hz Tripping characteristic: B Switching neutral: yes With interlocking device: yes Overvoltage category: 3 Pollution degree: 2 Ambient temperature during operation: -25..40 °C Width in pitch units: 2 Installation depth: 44.5 mm Flush mounting: no False tripping protection: no Protection class (IP): IP20 Connectable conductor cross-section solid: 1..16 mm² Connectable conductor cross-section stranded: 1..10 mm²Schneider Electric R9D01610 FI/LS switch: more detailsFI/LS switch Resi9 . 1 pole + N, 10A. B characteristic, rated residual current 30 mA, type A, rated breaking capacity 6kA, according to EN/IEC 61009-1. operating voltage (Ue) 230V AC, operating frequency 50 Hz, neutral position left. Residual current circuit breaker with integrated miniature circuit breaker. Mechanical red indicator in case of fault tripping of the circuit breaker and sperate mechanical red indicator in case of fault current tripping of the residual current circuit breaker on the front side of the device. Color RAL 9003, EAN: 3606489661953.
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
Mounting type | Top-hat rail |
number of poles | 2 |
Length | 100 mm |
Width | 85 mm |
Item number | 20027273 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer No. | R9D01610 |
Release date | 16.3.2022 |
External links |
Circuit breaker type | Miniature circuit-breaker/residual current circuit-breaker combination |
Mounting type | Top-hat rail |
number of poles | 2 |
Tripping characteristic | B |
Rated current | 10 A |
Rated voltage | 230 V |
voltage type | AC |
Insulation voltage (Ui) | 400 V |
Residual current | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | Spain |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 10,48 kg |
Climate contribution | EUR 0,26 |
Items per sales unit | 1 pcs. |
Length | 100 mm |
Width | 85 mm |
Height | 40 mm |
Product Safety |
Length | 10 cm |
Width | 4 cm |
Height | 8 cm |
Weight | 200 g |
30-day right of return
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Siemens0 %
- 5.ABB0,1 %
- 5.Schneider Electric0,1 %
- 7.Hager0,3 %
- 8.Steffen0,4 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 2.Steffen0,6 %
- 3.Eaton0,7 %
- 4.Schneider Electric1,6 %
- 5.Siemens2,7 %
- 6.ABB3,1 %