The ComPacT NSX250H is a complete, space- and switching capacity-optimized, fixed 4P3D compact circuit breaker. It is an optimal choice for all standard and special applications. The short-circuit breaking capacity (Icu) is 70 kA rms at 415 VAC 50/60 Hz. The operating voltage is 440 VAC 50/60 Hz. This product includes an electronic MicroLogic 7.2 E Vigi trip unit with a rated current of 160 A and an integrated adjustable residual current protection. The MicroLogic 7.2 E Vigi trip unit provides adjustable long-time, short-time, and instantaneous protection. MicroLogic 7.2 E Vigi features a built-in display for fine-tuning and monitoring energy usage. This 4-pole version (140 mm x 161 mm x 86 mm) comes with a variety of optional features and accessories. It complies with international standards (IEC 60947), CCC, EAC, and marine specifications. The ComPacT NSX250H is part of Schneider Electric's EcoStruxure Power architecture.
Circuit breaker type | Circuit breaker |
number of poles | 4 |
Mounting type | Built-in installation |
Item number | 33627905 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | C25H47E160 |
Release date | 17.5.2023 |
Circuit breaker type | Circuit breaker |
Mounting type | Built-in installation |
Mounting type | Screw fastening |
number of poles | 4 |
Tripping characteristic | Sluggish --- |
Rated current | 0.03 A |
voltage type | AC/DC |
Protection type (IP code) | IP40 |
Country of origin | Poland |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Product Safety |
30-day right of return if unopened
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0,1 %
- 5.ABB0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- Schneider ElectricNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 1.Brennenstuhl0 %
- 2.Steffen0,3 %
- 3.Schneider Electric1,2 %
- 4.ABB1,7 %
- 5.Siemens3,1 %