Siemens RCD type 63A Npol. 500mA 400V
rated current2
Residual current (rated differential current)2
Product details
Siemens Digital Industry Residual Current Circuit Breaker 5SV3746-6
Manufacturer: Siemens Digital Industry
Designation: Type A Residual Current Circuit Breaker, 500 mA, 63 A
Type: 5SV3746-6
Number of Poles: 4
Rated Voltage: 400 V
Rated Current: 63 A
Rated Residual Current: 0.5 A
Rated Insulation Voltage Ui: 2000 V
Rated Impulse Voltage Uimp: 6 kV
Power Loss: 3.9 W
Mounting Type: DIN Rail
Residual Current Type: A
Selective Type: No
Time Delay Type: No
Short-Circuit Strength (Icw): 10 kA
Impulse Current Strength: 1 kA
Voltage Type: AC
With Locking Device: Yes
Frequency: 50 Hz
Additional Devices Possible: Yes
Protection Class (IP): IP20
Width in Division Units: 4
Installation Depth: 70 mm
Ambient Temperature During Operation: -25..45 °C
Pollution Degree: 2
Connectable Conductor Cross-Section Multi-Wire: 0.75..35 mm²
Connectable Conductor Cross-Section Single-Wire: 0.75..35 mm²
RAL Number (similar): 7035
Explosion Protected: No
Siemens Digital Industry Residual Current Circuit Breaker 5SV3746-6: Additional Details
Residual Current Circuit Breaker, 4-pole, Type A, In: 63 A, 500 mA, Un AC: 400 V
The SENTRON 5SV3 Residual Current Circuit Breaker provides comprehensive protection for people and property against electric shock. These circuit breakers offer reliable safety during installation due to the standard included gripping and touch protection. With the convenient slider manual operation, you can easily detach the circuit breakers from the DIN rail or busbar assembly without tools. The data matrix code on the device provides quick access to all technical data in the Siemens Industry Online Support App. SENTRON protective devices can be extensively expanded with the comprehensive accessories from the system modular kit. Optimal technology for your safety - only from Siemens.
EAN: 4001869427904.
Circuit breaker type | Fault current circuit breaker |
Length | 70 mm |
Width | 70 mm |
number of poles | 4 |
Mounting type | Top-hat rail |
Item number | 13052017 |
Manufacturer | Siemens |
Category | Residual-current device |
Manufacturer no. | 5SV3746-6 |
Release date | 7.4.2020 |
Colour | Grey |
Exact colour description | RAL number (similar)7005 |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Tripping characteristic | A |
Rated current | 63 A |
Rated current | 0.5 A |
Rated voltage | 400 V |
voltage type | AC |
Rated insulation voltage Ui | 2000 V |
Residual current (rated differential current) | 0.50 A |
Protection type (IP code) | IP20 |
Country of origin | Germany |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Siemens fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 70 mm |
Width | 70 mm |
Height | 90 mm |
Product Safety |
30-day right of return if unopened
Compare products
Goes with
Reviews & Ratings
Statutory warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0,1 %
- 5.ABB0,2 %
Statutory warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Schneider ElectricNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Galaxus- 3.Schneider Electric1,4 %
- 4.ABB2,1 %
- 5.Siemens2,9 %
- 6.Eaton3,8 %
- 7.Hager5 %